swin¶
Specify the size of the support (i.e., the rate of change) for spline-based surface definitions (see srfm (elec)). The syntax is:
swin {win}
where win
is a floating point number for the spline window width (in Å).
Usually 0.3 Å.</p>
Note that, per the analysis of Nina, Im, and Roux (article)</a>, the force field parameters (radii) generally need to be adjusted if the spline window is changed.